Wearable intelligence battery testing System
CT-9008-5V6.5A-SMB
  • Size of Each Unit (W*D*H)(mm)
    W*D*H: 443*615*125(mm)
  • AC Input
    AC 220V +10%/ -20%, 50Hz;
  • Resolution
    AD: 16bit;DA: 16bit
  • Input Impedance
    ≥ 500MΩ 开机状态(关机时漏电流为100uA)
  • Input Active Power
    500w
  • Channel Characteristics
    四量程 宽动态范围 高速采样 高精度
  • Channel Control Mode
    Independent Control
  • Voltage

    Constant Voltage Range Control

    Charging:0.7 V~5V; 

    Discharging:0.7 V~5V (Clamp Line Length: 0.5m );


    Minimum Discharge Voltage

    0.7 V (Clamp Line Length: 0.5m );


    Accuracy

    ± 0.02% of FS;


    Stability

    ± 0.005% of FS;

  • Current

    Output Range per Channel

    Range 1:  0.1uA---150uA;

    Range 2:150uA---5mA;

    Range 3:5mA---150mA;

    Range 4:150mA---5A;



    Accuracy

    ± 0.02% of FS;


    Constant Voltage Cut-off Current

    2μA;0.01mA;0.02mA;


    Stability

    ± 0.005% of FS;

  • Power

    Single Channel Maximum Output Power: 25W; 

    Stability: ± 0.01% of FS;

  • Time

    Current Response Time (10%FS~90%FS)

    ≤100μS (10% to 90% or 90% to 10%);

     

    Step Time Range

    ≥10ms

  • Data Record

    Data Recording Conditions


    Time △t:≥10ms;

    Voltage △U:≥1mV;

    Current △I:≥100nA;



    Data Acquisition Frequency

    100Hz; (Continuous Charge & Discharge Mode);

  • Charge

    Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging, Constant Resistance Charging;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity, Energy, Power;

  • Discharge

    Discharge Mode: Constant Current Discharge, Constant Power Discharge and Constant Resistance Discharge;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity;

  • DCIR Test
    Support DCIR Working Steps
  • Cycle Life

    Cycle Test Range: 1~65535 times;

    Single Cycle Steps: 254; 

    Loop nesting: it has the function of nested loop and supports up to 4 levels of nesting;

  • Protect

    Software Protection

    Power down Data Protection;

    Function of Offline Test;

    The safety protection conditions can be set, and the setting specs include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit, Voltage Fluctuation Protection, Current Fluctuation Protection;

  • Voltage and Current Sampling
    Four Wire Connection
  • Database
    Adopting MySQL database to centralized manage testing data.
  • Communication Mode of Upper Computer
    Based on TCP/ IP Protocol
  • Data Output Mode
    EXCEL2003,2010、TXT
  • Communication Interface
    Network Interface
  • Total Number of Channels
    8
  • Clamp Type
    Universal Clamps
  • Server Operating System
    Windows 7  64Bit
  • Working Temperature Range
    25±5℃ (Accuracy Assurance),25±20℃ (Extreme Working Temperature);
  • Storage Temperature Range
    0~60℃
  • Relative Humidity Range of Working Environment
    ≤70% RH(There is no condensation of moisture.)
  • Relative Humidity Range of Storage Environment
    ≤80% RH(There is no condensation of moisture.)
  • Clamp Picture
    A705-P-QS-B
    PCB Coin Cell Clamps
    A705-P5-45B+(-)
Neware and Cookies