4 Range Simulation Battery Testing System
CT-8000
  • Each Unit Size (W*D*H)(mm)
  • AC Input
    AC 380V ±10% / 50Hz
  • Input Active Power
    5671W
  • Resolution
    AD:16bit;DA:16bit
  • Input Impedance
    ≥1kΩ
  • Voltage

    Constant Voltage Range Control: 0.025V~5V;

    Minimum Discharge Voltage: 0V;

    Accuracy: ± 0.05% of FS;

    Stability: ± 0.05% of FS;

  • Current

    Output Range per Channel

    Range 1: 10A, Range 2: 20A, Range 3: 30A, Range 4: 40A;

    Accuracy: ± 0.05% of FS;


    Constant Voltage Cut-off Current

    Range 1: 0.02A, Range 2: 0.04A, Range 3: 0.06A, Range 4: 0.08A;

    Stability: ± 0.05% of FS;

  • Power

    Single Channel Maximum Output Power: 200W;

    Stability: ± 0.1% of FS;

  • Time

    Current Response Time (10%FS~90%FS)

    Maximum current rise time: 10ms;


    Step Time Range

    ① ≤(365*24) h/step; ②Time Format Support  00:00:00:00(h, min, s, ms)

  • Data Acquisition

    Data Acquisition Conditions

    Minimum Time Interval: 10ms;

    Minimum Voltage Interval: 10mV;

    Minimum Current Interval: (Range 1: 0.02A; Range 2: 0.04A; Range 3: 0.06A; Range 4: 0.08A;


    Data Acquisition Frequency

    100Hz;

  • Charge

    Charging Mode: Constant Current Charging, Constant Voltage Charging, Constant Current/ Constant Voltage Charging, Constant Power Charging, Pulse Step, Simulation Step;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -△V;

  • Discharge

    Discharge Mode: Constant Current Discharge, Constant Voltage Discharge, Constant Power Discharge and Constant Resistance Discharge;

    Cut-off Conditions: Voltage, Current, Relative Time, Capacity;

  • Pulse Mode

    Charging: Constant Current Mode and Constant Power Mode;

    Discharge: Constant Current Mode and Constant Power Mode;

    Minimum Pulse Width: 500ms;

    Number of Pulses: A Single Pulse Step Supports 32 Different Pulses;

    Continuous Switching of Charge and Discharge: One Pulse Step can Realize Continuous Switching from Charge to Discharge;

    Cut off Conditions: Voltage, Relative Time;

  • Cycle Life

    Cycle Test Range: 1~65535 times;

    Number of Single Cycle Steps: 254;

    Loop Nesting: It has the Function of Nested Loop and Supports Up to 3 Levels of Nesting;

  • Simulation

    Charging Mode: Current and Power;

    Discharge Mode: Current and Power;

    Cut off Condition: Time, Line Number;

    Continuous Switching Between Charge and Discharge: A Simulated Step can Realize Continuous Switching from Charge to Discharge;

    Step File Line Limit:100000;

  • DCIR Test
    Support DCIR calculating with user defined point.
  • Parallel Mode
    It can support up to 4 channels in parallel, and pulse is not supported after parallel.
  • Protect

    Power down Data Protection;

    The safety protection conditions can be set, and the setting specs include: voltage upper limit, voltage lower limit, current upper limit, current lower limit and delay time;

    Function of Offline Test.

  • IP Protection Degree
    Protection Degree: IP20
  • Channel Characteristics
    Constant current and constant voltage adopt double closed loop structure.
  • Channel Control Mode
    Independent Control
  • Voltage and Current Sampling
    Four Wire Connection
  • Noise
    <85dB
  • Database
    Adopting MySQL database to centralized manage testing data.
  • Communication Mode of Upper Computer
    Based on TCP/ IP Protocol
  • Server Disk Configuration
    500GB
  • Server Operating System
    Windows 7
  • Leakage Current
    0.005mA
  • Data Output Mode

    EXCEL 2003, 2010; 

    TXT.

  • Communication Interface
    Network Interface
  • Total Number of Channels
    16
  • Working Temperature Range
    0℃~40℃(Within the range of 25±10℃, accuracy drift is 0.005% of FS /℃)
  • Storage Temperature Range
    -10℃~50℃
  • Relative Humidity Range of Working Environment
    ≤70% RH(There is no condensation of moisture.)
  • Relative Humidity Range of Storage Environment
    ≤80% RH(There is no condensation of moisture.)
  • Auxiliary Channel

    Type of Auxiliary Channel: Temperature and Voltage;

    Temperature Range: - 25 ℃ ~ 110 ℃ (Thermistor);

    Temperature Accuracy: ±1 ℃ (Line length within 2m);

    Temperature Resolution: 0.1 ℃;

    Voltage Range: 0V ~ 5V;

    Voltage Accuracy: ± 0.1% of FS;

  • Number of Temperature Auxiliary Channels per Channel
    Up to 248 Temperature Auxiliary Channels.
  • Number of Auxiliary Channels with Voltage per Channel
    Up to 248 Voltage Auxiliary Channels
  • Auxiliary Channel Protection Conditions
    Auxiliary Channel Protection Conditions can be Set, and the settable Specs include: Temperature Upper Limit, Temperature Lower Limit, Voltage Upper Limit, Voltage Lower Limit and Cell Differential Pressure.